Applied-motion RS-232 Bedienungsanleitung Seite 215

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 320
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 214
215
920-0002 Rev. I
2/2013
Host Command Reference
VL - Voltage Limit
Compatibility: High-voltage Stepper Drives (STAC5, STAC6 only)
Specifies the maximum voltage that will be applied to the motor by the PWM outputs on the drive.
Normally this is set to 100% for modern step motors. Some inexpensive motors are constructed with less robust
winding insulation, and require this voltage to be limited. In these rare cases, VL may be lowered. This will
directly impact motor performance, but will allow the drive to control a wider variety of motors.
Command Details:
Structure VL{Parameter #1}
Type BUFFERED
Usage READ / WRITE
Non-Volatile YES
Register Access None
Parameter Details:
Parameter #1 PWM Duty Cycle
- units
- range 10 - 1000 (1.0% - 100.0%)
Examples:
Command Drive sends Notes
VL1000 - Maximum voltage applied to the motor: 100.0% (default)
VL VL = 1000
VL500 - Maximum voltage applied to the motor: 50.0%
VL VL=500
Seitenansicht 214
1 2 ... 210 211 212 213 214 215 216 217 218 219 220 ... 319 320

Kommentare zu diesen Handbüchern

Keine Kommentare