Applied-motion STM23R-2ND Bedienungsanleitung Seite 7

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 24
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 6
7
STM23R Hardware Manual
920-0056C
5/5/2015
Connecting the Power Supply
If you need information about choosing a power supply, please read the sec-
tion
Choosing a Power Supply
.
• Connect the power supply “+” terminal to the connector terminal labeled
V+”.
• Connect power supply “-” to the connector terminal labeled “V-”.
• Use 18-20 gauge stranded wire.
e STM23R contains an internal fuse that connects to the power supply +
terminal. is fuse is not user replaceable. If you want to install a user service-
able fuse in your system install a fast acting 4 amp fuse in line with the + power supply lead.
Be careful not to reverse the wires. Reverse connection will destroy your drive, void your
warranty and generally wreck your day.
If you plan to use a regulated power supply you may encounter a problem with regeneration. If you rapidly
decelerate a load from a high speed, much of the kinetic energy of that load is transferred back to the power
supply. is can trip the overvoltage protection of a switching power supply, causing it to shut down. We oer
the RC-050 “regeneration clamp” to solve this problem. If in doubt, buy an RC-050 for your rst installation. If
the “regen” LED on the RC-050 never ashes, you don’t need the clamp.
RC-050 Regen Clamp
regen LED
1 2 3 4 5 6 7 8 1 2 3 4
STEP+
STEP
-
DIR+
DIR
-
EN+
EN
-
OUT+
OUT
-
V-
V
+
S/RSETUP
Seitenansicht 6
1 2 3 4 5 6 7 8 9 10 11 12 ... 23 24

Kommentare zu diesen Handbüchern

Keine Kommentare