STR4/8 Hardware Manual
920-0030J
5/12/2015
Switch
Motor
Drive Current
Amps, peak of
sine
Max Power Supply Current (A)
24VDC 48VDC 60VDC
0
reserved for custom motors1
2
3 HT23-603 6 4.4 4.0 4.0
4 HT23-394/594 3.4 1.9 2.0 n/a
5 HT23-398/598 5 3.2 3.3 n/a
6 HT23-401/601 5 3.2 3.4 n/a
7 HT24-100 3.36 2.6 2.3 2.0
8 HT24-105 4.8 5.2 3.2 2.7
9 HT24-108 4.8 4.3 3.4 2.9
A HT34-485 8 5.1 5.0 5.0
B HT34-486 8 5.2 4.6 4.4
C HT34-487 8 5.2 5.4 5.3
D HT34-504 7.56 4.8 4.2 4.0
E HT34-505 7.56 4.4 4.2 4.2
F HT34-506 6.72 3.5 3.2 3.3
Table 2: STR8 Power Supply Current
All motors connected in parallel, except HT24 which have four leads.
Regeneration
If you plan to use a regulated power supply you may encounter a problem with regeneration.
If you rapidly decelerate a load from a high speed, much of the kinetic energy of that load is
transferred back to the power supply. is can trip the overvoltage protection of a switching
power supply, causing it to shut down. If you have a high inertia load running at high speed an
unregulated supply may be beer. It has large capacitors for storing energy coming back from
the drive. ey are also less expensive. See previous section on
Connecting the Power Supply
for details on the RC-050 regeneration clamp.