Applied-motion STR4 Bedienungsanleitung Seite 16

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 46
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 15
16
STR4/8 Hardware Manual
920-0030J
5/12/2015
FAULT Output
e STR drives feature a digital FAULT output. is output closes
to signal a fault condition.
is output can be used to drive LEDs, relays and the inputs of
other electronic devices like PLCs. e “+” (collector) and “-” (emier) terminals of the output
transistor are available at the connector. is allows you to congure the output for current
sourcing or sinking.
Diagrams of each type of connection follow.
Do not connect the output to more than 30VDC.
e current through the output terminal must not exceed 80 mA.
Sinking Output
STR
5-24 VDC
Power Supply
+
Load
FAULT-
FAULT+
!
STR
5-24 VDC
Power Supply
+
Load
FAULT-
FAULT+
Sourcing Output
Driving a Relay
STR
FAULT-
FAULT+
1N4935 suppression diode
5-24 VDC
Power Supply
+
relay
FAULT+
FAULT-
Seitenansicht 15
1 2 ... 11 12 13 14 15 16 17 18 19 20 21 ... 45 46

Kommentare zu diesen Handbüchern

Keine Kommentare