
Alarm Codes
Intheeventofadrivefaultoralarm,thegreenLEDwillashoneortwotimes,followedbyaseriesofredashes.epaern
repeats until the alarm is cleared. Faults disable the motor and can be cleared by cycling power to the drive or toggling the
enable input. e “power supply voltage too low alarm” does not disable the motor and will self-clear aer 30 seconds. It can
be cleared sooner by cycling power to the drive or toggling the enable input.
404 Westridge Drive Watsonville, CA 95076
Tel (831) 761-6555 (800) 525-1609 Fax (831) 761-6544
www.applied-motion.com
Power and Motor Connector Signal Connector
Connector Diagrams
Code Error
solid green no alarm, motor disabled
flashing green no alarm, motor enabled
flashing red configuration or memory error; Contact factory for assistance.
1 green, 4 red power supply voltage too high fault
1 green, 5 red over current / short circuit fault
1 green, 6 red open motor winding fault
2 green, 3 red internal voltage out of range fault
2 green, 4 red power supply voltage too low alarm
V+
V
–
A–
B+
B
–
A+
STEP+
STEP
–
DIR–
EN+
EN
–
FAULT+
FAULT–
DIR+
920-0030G
12/12/2012
Kommentare zu diesen Handbüchern